(Українська) MOHR CUTTER 80
Sorry, this entry is only available in Ukrainian and Russian.
Poor sheet feeding on the register table.
Then there are two possible causes:
*Especially static charge occurs in dry warm air, because the charge, which is produced on contact surfaces, can’t be quickly disposed from paper. And sheets cling to the parts of machine, which partially leads to the considerable disorders. Especially the satin paper is susceptible for electrostatic charge.
Together with start-up problems, which are caused by electrostatic, a tendency to form dust increases. In this case discharged devices or anti-static spray can help. Also the increase of humidity around the folding machine can help. When the humidity is 50 –55 % and the temperature is 20-23 C the electrostatic charge occurs more rarely..